NANO-500 Micro-Spectrophotometer with Fluorometer, 200-800 nm
Need absorbance and fluorescence quantification in one instrument? The NANO-500 measures 0.5-2 µL samples from 200-800 nm and adds a built-in fluorometer mode with dsDNA sensitivity down to 0.5 pg/µL. Sold in Canada by Luna Nanotech of Markham, Ontario, with prices in Canadian dollars. Contact us with questions or for a quote.
The NANO-500 combines a 200-800 nm full-spectrum micro-volume spectrophotometer with a built-in fluorometer in one instrument. Measure DNA, RNA and protein absorbance from 0.5-2 µL, then switch to fluorescence mode for highly sensitive dsDNA quantification, without moving samples between two devices.
- Absorbance and fluorescence: UV-Vis micro-volume measurement plus a fluorometer mode with dsDNA sensitivity down to 0.5 pg/µL.
- Very wide concentration range: detects dsDNA from 2 to 15,000 ng/µL, so most samples need no dilution.
- Three path lengths: 0.05 mm, 0.2 mm and 1.0 mm cover both concentrated and dilute samples.
- OD600 cuvette mode: an LED-based cuvette mode measures bacterial culture density.
- Standalone operation: Android-based software, no computer connection required.
Catalogue number AS-11060-00.
Technical Specifications
- Model: NANO-500 (catalogue no. AS-11060-00)
- Wavelength range: 200-800 nm
- Sample volume: 0.5-2.0 µL (micro-volume mode)
- Path length: 0.05 mm, 0.2 mm and 1.0 mm
- Light source: xenon flash lamp
- Detector: 2048-element linear CCD array
- Wavelength accuracy: ±1 nm; spectral resolution 3 nm or better
- Absorbance range: 0.04-300 A (10 mm equivalent at 260 nm)
- Nucleic acid detection range: 2-15,000 ng/µL (dsDNA)
- Fluorometer mode: dsDNA sensitivity 0.5 pg/µL; standard blue LED excitation 460 ± 20 nm, emission 525-570 nm
- Cuvette mode light source: LED (OD600)
- Software: Android system
- Dimensions (W x D x H): 208 x 320 x 186 mm
Frequently Asked Questions
What is the difference between absorbance mode and fluorometer mode?
Absorbance mode measures DNA, RNA and protein across 200-800 nm and detects dsDNA from 2 to 15,000 ng/µL. Fluorometer mode uses blue LED excitation (460 ± 20 nm, emission 525-570 nm) to quantify dilute dsDNA down to 0.5 pg/µL.
Why does it have three path lengths?
The 0.05 mm, 0.2 mm and 1.0 mm path lengths let it cover both concentrated and dilute samples, so most samples need no dilution.
Do I need a computer to use it?
No. It runs on Android-based software and works as a standalone instrument.
How is the NANO-500 different from the NANO-300?
The NANO-500 adds the fluorometer mode and a 0.05 mm path length, and its dsDNA range reaches 15,000 ng/µL, compared with 4,500 ng/µL on the NANO-300.