FlexA-200HT Absorbance Microplate Reader with Cuvette, 200-1000 nm
A full-wavelength absorbance reader that handles both microplates and single cuvettes. The FlexA-200HT covers 200-1000 nm, reads 96-well and 384-well plates, and has an independent cuvette slot with incubation. Sold in Canada by Luna Nanotech of Markham, Ontario, with prices in Canadian dollars. Contact us with questions or for a quote.
The FlexA-200HT is a full-wavelength absorbance microplate reader with an independent cuvette slot and an incubation function. It covers 200-1000 nm using a monochromator, handles 96-well and 384-well plates (with or without lids), and runs on a 10-inch Android touch screen, so you can read microplates and single cuvettes on one instrument.
- Plates and cuvettes: read microplates for ELISA-type assays, or switch to the independent cuvette slot for individual samples, with endpoint, kinetic, spectral scanning and standard-curve functions.
- Full wavelength flexibility: choose any wavelength from 200 to 1000 nm instead of being limited to fixed filters.
- Incubation: temperature control from room temperature + 4 °C up to 45 °C for kinetic and temperature-sensitive assays, with ±0.5 °C uniformity at 37 °C. The cuvette can be incubated too.
- Fast reading: a 96-well plate in about 8 seconds in fast mode.
- Easy operation: built-in software for standalone use, plus optional ReaderIt-II PC software.
Catalogue number AS-19020-00.
Technical Specifications
- Model: FlexA-200HT (catalogue no. AS-19020-00), absorbance with independent cuvette slot
- Detection: absorbance; 96-well and 384-well plates, with or without lid; cuvette mode
- Optical system: monochromator, 1 nm step; wavelength range 200-1000 nm
- Light source: xenon flash lamp (over 109 flashes)
- Wavelength accuracy: 2 nm; repeatability 0.2 nm; bandwidth under 2.5 nm
- Reading range: 0-4.0 Abs
- Detection system: two silicon photodetectors (measurement and reference)
- Linearity at 450 nm: R² ≥ 0.999 (0.0-3.0 Abs)
- Absorbance accuracy at 450 nm: ±(1.0% + 0.003 Abs) from 0 to 2.0 Abs; ±2.0% above 2.0 Abs
- Measuring speed (96-well, end point): about 8 s fast mode; about 28 s accurate mode
- Shaking: linear, 3 adjustable speeds
- Incubation: room temperature + 4 °C up to 45 °C; accuracy ±0.5 °C and uniformity ±0.5 °C at 37 °C; cuvette can also be incubated
- Cuvette mode: independent cuvette software for endpoint, kinetics, spectral scanning and standard curves
- Display: 10-inch capacitive touch screen, Android system; built-in software for standalone use, optional ReaderIt-II PC software (sold separately)
- Storage: 16 GB, over 20,000 data files
- Ports: USB A x2, USB B x1, network port x1
- Power: AC 100-240 V, 50-60 Hz, 2 A
- Operating conditions: 10-40 °C, 30-80% relative humidity, non-condensing
- Dimensions (W x D x H): 300 x 500 x 260 mm
- Weight: 15.5 kg
Frequently Asked Questions
What does the cuvette slot do?
It lets you read single cuvettes independently of the plate, with its own software for endpoint, kinetics, spectral scanning and standard curves. The cuvette can be incubated too.
Which plates does the FlexA-200HT read?
96-well and 384-well plates, with or without lids.
What incubation range does it have?
Room temperature + 4 °C up to 45 °C, with ±0.5 °C uniformity at 37 °C.
How fast does it read a plate?
About 8 seconds for a 96-well plate in fast mode.
How is the FlexA-200HT different from the FlexA-200?
The FlexA-200HT adds the independent cuvette slot. Both cover 200-1000 nm.